ORIGINAL ARTICLE
Year : 2014  |  Volume : 4  |  Issue : 4  |  Page : 32-37
Comparison of canine retraction by in vivo method using four brands of elastomeric power chain


1 Department of Orthodontics and Dentofacial Orthopaedics, Drs. Sudha and Nageswara Rao Siddhartha Institute of Dental Sciences, Chinaoutpally, Gannavaram, Andhra Pradesh, India
2 Department of Oral Surgery, School of Dentistry, Zawia University, Zawia, Libya
3 Department of Orthodontics and Dentofacial Orthopaedics, KLR Lenora Institute of Dental Sciences, Rajahmundry, India
4 Government Dental College and Hospital, Gunadala, Vijayawada, Andhra Pradesh, India
5 Department of Orthodontics and Dentofacial Orthopaedics, Saraswathi Dhanwantari Dental College, Parbhani, Maharashtra, India
6 Department of Orthodontics and Dentofacial Orthopaedics, RAMA Dental College, Kanpur, Uttar Pradesh, India

Date of Web Publication13-Nov-2014

Correspondence Address:
Ravi Krishna Kanuru
Department of Orthodontics and Dentofacial Orthopaedics, Drs. Sudha and Nageswara Rao Siddhartha Institute of Dental Sciences, Chinaoutpally, Gannavaram 521 101, Andhra Pradesh, India

Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2231-0762.144586

Rights and Permissions

   Abstract 

Objective: To investigate the amount of space closure by movement of canines into the extraction spaces using four brands of elastomeric power chains (EPCs) by intraoral application with pre-adjusted appliance for 6 weeks. Materials and Methods: The sample size calculation was based on the studies of Boester and Johnston and also with repeated measures analysis of variance (ANOVA) continuous data for force degradation, standard deviation of 24.9 g, and also from a pilot study, which totaled to around 17 patients with a mean age of 20 ± 2 years and receiving fixed orthodontic treatment that required retraction of canines into the premolar extraction spaces in all four dental arch quadrants. Four brands of EPCs, namely the Ormco, 3M Unitek, Rocky Mountain, and Highland, which were closed-link with five loops delivering less than or equal to 250 g were used. The rates of canine retraction were measured between the attachment points on the canine bracket hook and first molar hook using a Mitutoyo Digital Vernier Caliper at the time of first application, after 3 weeks of use, and at the end of 6 weeks of use, and were subjected to statistical calculations. Results: The distances recorded from canine retraction were similar with slight differences noticed in the four brands of EPCs. However, no statistically significant difference was observed in relation to the EPCs. Conclusion: Although all brands of the EPCs produced space closure of canines, it was observed that not much of a significant difference existed among the products tested.


Keywords: Canine retraction, elstomeric power chain, premolar extraction


How to cite this article:
Kanuru RK, Azaneen M, Narayana V, Kolasani B, Indukuri RR, Babu FP. Comparison of canine retraction by in vivo method using four brands of elastomeric power chain. J Int Soc Prevent Communit Dent 2014;4, Suppl S1:32-7

How to cite this URL:
Kanuru RK, Azaneen M, Narayana V, Kolasani B, Indukuri RR, Babu FP. Comparison of canine retraction by in vivo method using four brands of elastomeric power chain. J Int Soc Prevent Communit Dent [serial online] 2014 [cited 2020 Sep 28];4, Suppl S1:32-7. Available from: http://www.jispcd.org/text.asp?2014/4/4/32/144586



   Introduction Top


Arch-length-to-tooth-mass discrepancy patients require extraction of teeth and closure of those spaces to correct their malocclusion. There are different mechanical methods used in orthodontic practice to move teeth, such as using various types of elastic materials and coil springs. [1] During the past few years, elastomeric power chains (EPCs) have been used in preference to other retraction orthodontic materials because of their elastic properties, ease of application and requiring no patient co-operation, low cost, being relatively hygienic, and their irritation-free nature due to their smooth surface. [2]

Although these EPCs offer several advantages over other materials, in vitro tests (which fail to simulate in vivo intraoral conditions, including the amount of force applied initially, the action of oral flora and their by-products, and the possible synergistic effects of these variables) and some in vivo studies have reported decay of applied force over time. [1],[2],[3] This force decay has been related to the period of use, as well as the amount of stretch given to the EPCs. Even though this force decay was found to be significant in vivo, only a few studies [4],[5],[6],[7] have cited the possibility of differences in force decay properties of EPCs from two different manufacturers. Moreover, polyurethanes, from which EPCs are made by thermosetting polymer products of a step-chain reaction polymerization process, possessing a -(NH)-(C = O)-O- unit, are not inert materials; they are strongly affected by heat, moisture, and prolonged contact with enzymes. [8]

The varied and patented formulations of these materials also suggest that there may be variations in the in vivo performance of EPCs from different manufacturers, but the clinician has no way of predicting the performance of the EPCs other than by comparative trials. At the end of a 6-week time period, it would be desirable for the orthodontist to know the remaining space compared with the amount that is considered desirable for ongoing tooth movement. However, there is no information available so far, comparing the effects of four brands of EPCs on the rate of canine retraction during clinical use when they are usually left in place during tooth movement on using them for a period of 3-6 weeks. It was, therefore, felt to be of value to test the amount of space closure in vivo using four different brands of EPCs.


   Materials and methods Top


The sample size calculation was based on the repeated measures analysis of variance (ANOVA) continuous data for force degradation, standard deviation of 24.9 g, [8] and also from a pilot study, which totaled to around 17 patients with a mean age of 20 ± 2 years. Informed consent letters were given to the subjects who were willing to participate. The inclusion criteria were subjects undergoing extraction of their premolar teeth and retraction of their canines to correct crowding or protrusion of incisor teeth by fixed orthodontic treatment at the Orthodontic Clinic of the Faculty of Dentistry, Khon Kaen University.

Four brands of closed loop EPCs were tested as shown in [Figure 1]a and 1b, since it has been observed that a more consistent force level is likely to be delivered by a closed loop chain. [9],[10] The four brands were chosen since they were readily available without any waiting time.

An initial load/deflection test of the four brands using the Lloyd universal testing machine (LR30K; Lloyd instruments Ltd, Hampshire, UK) was carried out during the pilot test.
Figure 1: (a) EPCs employed in the study from left to right: a. Highland (Clear color); (b) Ormco (Grey color); c. 3M Unitek (Blue color); d. Rocky Mountain (Clear color)

Click here to view


A Correx gauge (Ispringen, Germany) was used for recording the force values. The accuracy of the Correx gauge was checked by calibrating it with the help of a Lloyd testing machine (LR30K; Lloyd instruments LtdD). Mitutoyo Digital Vernier caliper (Japan) was used for measuring the distance between the first molar hook and the canine hook. The test was initiated after banding and bonding during the final stages of alignment with round 0.16" stainless steel arch wire insertion as the normal protocol for canine retraction. Hooks on the canine bracket and first molar band were the attachment points for five closed loops of the EPCs. The patients were asked to return at the end of the third week and sixth week for measurements considering that they are expected to cover the most common appointment recall periods used by orthodontists, but still it depends on the clinician preference.

The EPCs obtained from four different manufacturers were assigned to each of the four dental arch quadrants for the subjects participating in this study, by applying intraorally in a sequential clockwise direction.

The principal investigator recorded the forces and distances at each visit of the subjects. To test measurement reliability, the principal investigator did repeated measures of stretching force and distance using fresh elastics for five patients as a pilot study. As the canine-molar distance in the subjects' oral cavity could not be made constant, there were small variations in the stretching forces and distances.

The amount of the stretching force was recorded with a Correx gauge [Figure 2] which is a standard instrument for measuring orthodontic force. Distance between the first molar hook and the canine hook was also recorded at the same time with a Mitutoyo Vernier Caliper [Figure 3].
Figure 2: Recording the amount of stretching force with a Correx gauge

Click here to view
Figure 3: Recording the distance between the first molar hook and the canine hook also was recorded with a Mitutoyo Digital Vernier Caliper

Click here to view



   Results Top


Measurements of distance changes between the canine and molar hooks

Due to loss of data, only 17 subjects' measurements were included in this analysis.

The amount of retraction force depends on the amount of extension of the EPC between canine and molar teeth, and as the canine is distalized, the retraction force of the EPCs reduces. For this reason, the changes in canine-molar distance were measured at the start and end of the third and sixth week test periods.

Descriptive statistics for distance changes between the canine and molar hooks

[Table 1] and [Figure 4] and [Figure 5] demonstrate the space closure achieved during 6 weeks of EPC use, represented by the reduction in distance between hooks on canine and molar orthodontic attachments. The mean differences of space closure from the time of initial application of EPC were 0.96 mm by the end of third week and 2.07 mm by the end of sixth week for Ormco EPC; 1.12 mm by the end of the third week and 2.02 mm by the end of the sixth week for 3M Unitek EPC; 1.00 mm by the end of third week and 1.92 mm by the end of sixth week for Rocky Mountain EPC; and 0.76 mm by the end of third week and 1.47 mm by the end of sixth week for Highland EPC.
Figure 4: Graph showing the mean reduction of distance between canine and molar hook (mm) from start to end of three and six weeks of intra-oral application of EPCs. (n=17)

Click here to view
Figure 5: Bar Graph showing the mean reductions of distance between canine and molar hook (mm) from start to end of three and six weeks of intra-oral application of EPCs (n=17)

Click here to view


Repeated measures ANOVA for comparing the mean reduction of distance between canine and molar hooks

Repeated measures ANOVA [Table 1] showed no significant differences on comparing the mean reduction of distance measurement at 3 and 6 weeks after placement for the four different brands of EPCs.
Table 1: Mean reduction of distance measurements at 3 and 6 weeks use of EPCs stretched between the canine and molar hooks (N=17)


Click here to view


Multiple comparisons [Table 2] showed that no significant differences (P > 0.05) existed after 3 and 6 weeks time intervals in the mean reduction of distance measurement for the four different brands of EPCs.
Table 2: Multiple comparisons for the mean reduction of distance measurements at 3 and 6 weeks of intraoral use of EPCs


Click here to view


Measurement of distance reduction based on percentage of initial distance recorded between canine and molar hooks

Descriptive statistics for distance reduction based on percentage of initial distance recorded between canine and molar hooks

To standardize the data and compensate for the variability in the initial distance among different subjects, the percentage reduction of distance from the time of placement till the end of test period in the oral cavity was calculated at 3 and 6 weeks intervals for each brand. Means and standard deviations of percentage reduction of distance during the 3 and 6 week test periods are presented in [Table 3]. There were not much notable variations between the different brands of EPC, both at 3 and 6 weeks intervals. After 6 weeks, the mean percentage reduction of distance among the four brands of EPCs ranged from 3.36 to 4.95%.
Table 3: Comparison of the percentage reduction of distance between canine and molar hooks at 3 and 6 weeks of intraoral application of EPCs (N=17)


Click here to view


[Figure 6] depicts the distance reduction based on the percentage of initial distance measurements.{Figure 5}
Figure 6: Graph showing the percentage reduction of distance between canine and molar hooks after three and six weeks of intra-oral application of EPCs. (n=17)

Click here to view


Repeated measure ANOVA comparisons among the different brands for distance reduction based on the percentage of initial distance measurement at 3 and 6 weeks after placement for the four different brands of EPCs

Repeated measures ANOVA was employed to test for any significant differences in the distance changes between canine and molar hooks based on the percentage of initial distance measurement at 3 and 6 weeks after placement for the four different brands of EPCs.

Repeated measures ANOVA and multiple comparison analysis [Table 4] showed that no significant differences (P < 0.001) existed after 3 and 6 weeks time intervals for the force degradation based on the percentage of initial force measurement.
Table 4: Multiple comparisons for distance changes compared as the initial percentage reduction of distance at 3 and 6 weeks of intraoral use of EPCs


Click here to view



   Discussion Top


It should be emphasized that the term "initial force" was reserved for the force values recorded when the material was taken from the manufacturer's spool and first stretched between the canine and molar hooks of the orthodontic appliance without pre-stretching before use. All types and sizes of polyurethane materials, regardless of the amount of stretch, showed a decrease in force with time when compared with the corresponding initial force, which is in agreement with the report of Eliades et al. [11],[12]

The present study confirms the previous findings that the force of EPCs is lost progressively over the period of application. [1],[5],[9],[12],[13],[14],[15] The most important property of EPC use in orthodontics depends on its ability to exert a clinically acceptable force level over a set period of clinical use. [8] The initial force used in this study ranged between 228.18 ± 30.21 g and 202.27 ± 43.82 g, depending on the canine molar distance and the particular EPC used. This force may be classed as "high," but there is significant variation in the recommended force for canine distalization, from 100 to 150 g, [16] up to 250 g, [17] and from 100 to 200 g. [18]

Decrease in force after a period of in vivo use results from the permanent extension of the EPCs called hysteresis, as well as by the masticatory forces being applied to the material, tooth movement, and also from degradation of the EPC material due to exposure to the oral environment. [19] However, the orthodontic appliance used was the same for all test patients, as described in the methodology. The primary objective of the study was to measure the overall effectiveness of the different brands of EPCs in the oral environment for 6 weeks. The other factor that can be considered during canine retraction is the friction between the arch wire and the bracket. The movement of the canine crown can be limited by the width of the periodontal ligament and the elastic capacity of the alveolar crest, which can also be a factor for canine retraction. Rate of canine retraction can also be increased when forces are immediately applied after tooth extraction, since the regenerative bone tissue refills the extraction socket within 3 weeks and becomes resistant and solid within 3 months. [20] The more resistant the bone tissue is, the slower becomes the rate of tooth movement.

The orthodontic EPCs with five loops were selected in this study because they clinically applied less than 250 g of initial force between the attachment points. It was noted in this study that different samples of EPC from Rocky Mountain Company when subjected to a load of 250 g on the universal testing machine showed different patterns of deflection [Figure 7], suggesting that manufacturing variations may exist in the material tested from the same spool.

Other studies [21],[22] have found differences in the elastic ligature properties. Therefore, if a strict quality control is not enforced during the manufacture of elastomeric chains, test results may be different.
Figure 7: Illustartion indicating Rocky Mountain EPC manufacturing defects

Click here to view



   Conclusion Top


  • Not much significant differences were found among the four brands of EPCs used
  • Regardless of the properties that EPCs possess, they are still a suitable choice as tooth-moving elements with acceptable force levels
  • The clinician might have more control when using EPCs than while using elastic rings which depends on continuous reapplication by the patient. An accurate estimation of the force is more difficult with polyurethane elastomeric materials because of the inability to accurately predict the amount of decay in the force originally applied
  • EPCs are fail-safe products since in the event of a patient missing the orthodontist's appointment, their timeframe of progressive degradation would preclude them from continuing to act beyond their planned effect.



   Acknowledgment Top


Financial interests, direct or indirect, for any of the authors do not exist for this article. Sources of outside support of the project are none for this article.

 
   References Top

1.
Halimi A, Benyahia H, Doukkali A, Azeroual MF, Zaoui F. A systematic review of force decay in orthodontic elastomeric power chains. Int Orthod 2012;10:223-40.   Back to cited text no. 1
    
2.
Dixon V, Read MJ, O'Brien KD, Worthington HV, Mandall NA. A randomized clinical trial to compare three methods of orthodontic space closure. J Orthod 2002;29:31-6.   Back to cited text no. 2
    
3.
Storie DJ, Fedrick R, Von Fraunhofer JA. Characteristic of a fluoride-releasing elastomeric chain. Angle Orthod 1994;64:199-210.   Back to cited text no. 3
    
4.
Nightingale C, Jones SP. A clinical investigation of force delivery systems for orthodontic space closure. J Orthod 2003;30:229-36.   Back to cited text no. 4
    
5.
Ash JL, Nikolai RJ. Relaxation of orthodontic elastomeric chains and modules in vitro and in vivo. J Dent Res 1978;55:685-90.   Back to cited text no. 5
    
6.
Bousquet JA Jr, Tuesta O, Flores-Mir C. In vivo comparison of force decay between injection molded and die-cut stamped elastomers. Am J Orthod Dentofac Orthop 2006;129:384-9.   Back to cited text no. 6
    
7.
Rock WP, Wilson HJ, Fisher SE. Force reduction of orthodontic elastomeric chains after one month in the mouth. Br J Orthod 1986;13:147-50.   Back to cited text no. 7
    
8.
Kuster R, Ingervall B, Burgin W. Laboratory and intra-oral tests of the degradation of elastic chains. Eur J Orthod 1986;8:202-8.   Back to cited text no. 8
    
9.
Wong AK. Orthodontic elastic materials. Angle Orthod 1976;46:196-205.   Back to cited text no. 9
    
10.
Baty DL, Volz JE, von Fraunhofer JA. Force delivery properties of colored elastomeric modules. Am J Orthod Dentofacial Orthop 1994;106:40-6.   Back to cited text no. 10
    
11.
Eliades T, Eliades G, Silikas N, Watts DC. Tensile properties of orthodontic elastomeric chains. Eur J Orthod 2004;26:157-62.   Back to cited text no. 11
    
12.
Bishara SE, Andreasen GF. A comparison of time related forces between plastic alastiks and latex elastics. Angle Orthod 1970;40:319-28.   Back to cited text no. 12
    
13.
Ren Y, Maltha JC, Kuijpers-Jagtman AM. Optimum force magnitude for orthodontic tooth movement: A systematic literature review. Angle Orthod 2003;73:86-92.   Back to cited text no. 13
    
14.
Brantley WA, Salander S, Myers CL, Winders RV. Effects of prestretching on force degradation characteristics of plastic modules. Angle Orthod 1979;49:37-43.   Back to cited text no. 14
    
15.
De Geneova DC, McInnes-Ledoux P, Weinberg R, Shaye R. Force degradation of orthodontic elastomeric chains-a product comparison study. Am J Orthod 1985;87:377-84.   Back to cited text no. 15
    
16.
Boester CH, Johnston LE. A clinical investigation of the concepts of differential and optimal force in canine retraction. Angle Orthod 1974;44:113-9.   Back to cited text no. 16
    
17.
Reitan K. Some factors determining the evaluation of forces in orthodontics. Am J Orthod 1957;43:32-45.   Back to cited text no. 17
    
18.
Quinn RS, Yoshikawa DK. A reassessment of force magnitude in orthodontics. Am J Orthod 1985;88:252-60.   Back to cited text no. 18
    
19.
Eliades T, Eliades G, Silikas N, Watts DC. In vitro degradation of polyurethane orthodontic elastomeric modules. J Oral Rehabil 2005;32:72-7.   Back to cited text no. 19
    
20.
Häsler R, Schmid G, Ingervall B, Gebauer U. A clinical comparison of the rate of maxillary canine retraction into healed and recent extraction sites-a pilot study. Eur J Orthod 1997;19:711-9.  Back to cited text no. 20
    
21.
Silva DL, Kochenborger C, Marchioro EM. Force degradation in orthodontic elastic chains. Rev Odonto Ciênc 2009;24:274-8.   Back to cited text no. 21
    
22.
Stevenson JS, Kusy RP. Force application and decay characteristics of untreated and treated polyurethane elastomeric chains. Angle Orthod 1994;64:455-67.  Back to cited text no. 22
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6], [Figure 7]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4]

This article has been cited by
1 The Effect of Submucosal Injection of Plasma-Rich Platelets on Blood Inflammatory Markers for Patients with Bimaxillary Protrusion Undergoing Orthodontic Treatment
Trefa Mohammed Ali Mahmood,Omar Fawzi Chawshli
International Journal of Inflammation. 2019; 2019: 1
[Pubmed] | [DOI]
2 Efficacy of elastic memory chains versus nickel–titanium coil springs in canine retraction: A two-center split-mouth randomized clinical trial
Mashallah Khanemasjedi,Mehrnaz Moradinejad,Pedram Javidi,Ozra Niknam,Nima Haghighat Jahromi,Vahid Rakhshan
International Orthodontics. 2017; 15(4): 561
[Pubmed] | [DOI]
3 Efficacité des chaînettes élastiques à mémoire versus les ressorts hélicoïdaux en NiTi pour la rétraction des canines : une étude clinique randomisée en bouche divisée en deux centres
Mashallah Khanemasjedi,Mehrnaz Moradinejad,Pedram Javidi,Ozra Niknam,Nima Haghighat Jahromi,Vahid Rakhshan
International Orthodontics. 2017; 15(4): 561
[Pubmed] | [DOI]
4 Accelerated tooth movement with piezocision and its periodontal-transversal effects in patients with Class II malocclusion
Sertac Aksakalli,Berra Calik,Burcak Kara,Seref Ezirganli
The Angle Orthodontist. 2016; 86(1): 59
[Pubmed] | [DOI]
5 Application of Elastomeric Chains in Orthodontics: Past, Present and Future
Amir Hossein Mirhashemi,Niloofar Farahmand,Elahe Soltanmohamadi Borujeni
Iranian Journal of Orthodontics. 2016; In Press(In Press)
[Pubmed] | [DOI]
6 Stiffness characteristics of splints for fixation of traumatized teeth
Meshari W. Ben Hassan,Lars Andersson,Peter W. Lucas
Dental Traumatology. 2015; : n/a
[Pubmed] | [DOI]



 

Top
Print this article  Email this article
 
  Search
 
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Article in PDF (1,512 KB)
    Citation Manager
    Access Statistics
    Reader Comments
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
   Introduction
    Materials and me...
   Results
   Discussion
   Conclusion
   Acknowledgment
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed2637    
    Printed51    
    Emailed1    
    PDF Downloaded184    
    Comments [Add]    
    Cited by others 6    

Recommend this journal