ORIGINAL ARTICLE
Year : 2016  |  Volume : 6  |  Issue : 2  |  Page : 142-148
A comparative analysis of the accuracy of implant master casts fabricated from two different transfer impression techniques


1 Department of Prosthodontics, Bharati Vidyapeeth Dental College, Pune, Maharashtra, India
2 Prosthodontics Private Practitioners, Pune, Maharashtra, India
3 Department of Pedodontics, Bharati Vidyapeeth Dental College, Pune, Maharashtra, India

Date of Web Publication15-Mar-2016

Correspondence Address:
Dr. Rupali Patil
Department of Prosthodontics, Bharati Vidyapeeth Dental College, Pune, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2231-0762.178747

Rights and Permissions

   Abstract 

Aim: This study evaluated and compared two impression techniques in terms of their dimensional accuracies to reproduce implant positions on working casts. Materials and Methods: A master model was designed to simulate a clinical situation. Impressions were made using four techniques: (1) Stock open tray (SOT) technique; (2) stock closed tray (SCT) technique; (3) custom open tray (COT) technique; and (3) custom closed tray (CCT) technique. Reference points on the hexagonal silhouette of the implant on master model and onto the analogs of the obtained master casts were compared after using the four impression techniques. Measurements were made using an optical microscope, capable of recording under 50x magnifications. The means and standard deviations of all the groups and subgroups were calculated and statically analyzed using analysis of variance (ANOVA) and Tukey's test. Results: The open tray impressions showed significantly less variation from the master model and all the techniques studied were comparable. Conclusion: All the techniques studied shown some distortion. COT showed the most accurate results of all the techniques.


Keywords: Closed tray impressions, custom trays, implants, open tray impression, stock tray, stock tray impressions


How to cite this article:
Patil R, Kadam P, Oswal C, Patil S, Jajoo S, Gachake A. A comparative analysis of the accuracy of implant master casts fabricated from two different transfer impression techniques. J Int Soc Prevent Communit Dent 2016;6:142-8

How to cite this URL:
Patil R, Kadam P, Oswal C, Patil S, Jajoo S, Gachake A. A comparative analysis of the accuracy of implant master casts fabricated from two different transfer impression techniques. J Int Soc Prevent Communit Dent [serial online] 2016 [cited 2019 Jul 23];6:142-8. Available from: http://www.jispcd.org/text.asp?2016/6/2/142/178747



   Introduction Top


Titanium endosseous implants have been used for more than four decades in various edentulous situations. The emergence and acceptance of implant dentistry have given clinicians a wide variety of new alternatives for fixed and removable rehabilitations. The overall success is the ultimate replacement of the missing tooth, and this can be achieved through established prosthodontic principles. Proper impression techniques for implant dentistry should not be different from those used in conventional dentistry; therefore, proper impression techniques remain one of the foundations for prosthetic reconstruction. Failure in recording correct impression results in imprecise fit between the fixture and prosthesis, resulting in the generation of considerable stresses and it may lead to mechanical failure of an implant.

According to Balouch et al.,[1] there are several methods to achieve passive fitness although no distinct protocol has been introduced in this field yet. It is now believed that the impression materials are significantly improved; so choosing the proper technique is of prime concern. According to a review of various studies by Prithviraj et al.[2] where there are three or fewer implants, there is no difference between the pick-up and transfer techniques. This study was conducted to find the most accurate impression technique, along with understanding the influence of tray type for transfer of intraoral position of implant fixtures on cast.


   Materials and Methods Top


Model preparation

A fully edentulous maxillary resin model was made with four implants placed in the anterior region. A wax model was prepared using edentulous maxillary Frasaco mold and then it was invested, dewaxed, and acrylized by using heat cure clear acrylic resin. A stent prepared from clear acrylic resin was used to guide for the placement of implants in the master model [Figure 1]. Four implants (External Hex Implant 4.0 mm × 10 mm, Threadform; BioHorizons Implant Systems, Inc. Birmingham, West Midlands, England), two in the region of the lateral incisor and in the premolar region, respectively, were placed since this is the minimum number of implants suggested to support fixed-removable, removable prosthesis for better result. The distances between four implants of master models were measured using an optical microscope by taking sharp points of the projected hexagonal silhouettes as reference points. These distances were recorded as: A to B––7.36 mm, B to C––13.95 mm, C to D––8.15 mm, and A to D––30.65 mm. They were taken as a standard for further comparisons [Figure 2].
Figure 1: Master model

Click here to view
Figure 2: Schematic representation of master model

Click here to view


Fabrication of trays

Stock metal and custom acrylic were used for the impressions. Custom impression trays were fabricated using autopolymerizing acrylic resin material with 3-mm spacer and four tissue stops, two each in the anterior and posterior regions. Twenty similar special trays were fabricated by duplication. Later, perforations of 2 mm were made before making an impression for mechanical retention.

Perforations with a diameter of 1 cm opposing the guiding pins were made on the stock and custom trays for the open tray impression technique such that transfer impression coping projected from those openings. [Figure 3] for closed tray impression technique, stock trays with rim lock border were used.
Figure 3: Tray selected for the study

Click here to view


Impression making

Forty polyether impressions (Impregum Penta; 3M Espe Dental AG, Seefeld, Germany) were made using Pentamix II (3M Espe Dental AG). Four impression groups were formed as follows;

  • Group 1: Stock open tray (SOT) technique
  • Group 2: Stock closed tray (SCT) technique
  • Group 3: Custom open tray (COT) technique
  • Group 4: Custom closed tray (CCT) technique.


Ten impressions were made for each group. Before making impressions for open and closed trays, impression post and abutment with ball top screw were attached to implants [Figure 4]. The material was allowed to polymerize for twice the manufacturers' recommended setting times to allow for optimum polymerization at room temperature rather than mouth temperature.
Figure 4: (a) Master model having abutment with ball top screw (b) Master model with impression post

Click here to view


Attachment of implant analogs

After retrieving the impression from the master model, implant analogs were attached to both open and closed tray impressions. In open tray impression technique once the impression was set, the guiding screws were removed and the impression posts were retrieved with the impression. Analogs were attached to the impression posts using the screws and the impression were poured with type IV dental stone.

In closed tray impression group, the impression was retrieved from the master model and the abutments were left with ball top screws. These were then disengaged from the model and attached to the laboratory analogs. The abutment with ball top screws and analogs assemblies were placed into their respective sites in the impressions and the casts were poured.

Preparation of casts

All the impressions were stored for 24 h before pouring. Later, Type IV gypsum (Kalrock, super hard die stone, Class IV, Kalabhai Karson Ltd., Mumbai, Maharashtra, India) was mixed according the manufacturers' directions (23 cc water and 100 gm powder). The casts were separated from the impression after 1 h [Figure 5].
Figure 5: Casts poured using stock closed tray SCT, stock open tray SOT, custom closed tray CCT, custom open tray COT

Click here to view


Measurement of casts

All the casts were stored at room temperature for a minimum of 24 h before the measurements were made. A calibrated optical microscope (Depew, NY, USA) was used to record the positional accuracy of the implants. All the measurements were made under 50x magnifications. The optical microscope allowed measurement of linear distances with an accuracy of 0.01 mm (1 µm).

The interimplant distance was measured using the optical microscope between the three reference margins of the implant, i.e., from A to B, B to C, and C to D. The longer distance from A to D was measured using electronic digital micrometer having a measurement capacity of 1 mm since the optical microscope cannot measure distances over 16 mm.

The mean and standard deviation were calculated for models and casts for each dimension for all the groups. All P values were obtained using one-way analysis of variance (ANOVA) test and intragroup comparison was done using Tukey's test.


   Results Top


Comparison of distance between A and B

By using ANOVA test P < 0.05, there is a significant difference between SOT, SCT, COT, and CCT with respect to mean distance. Minimum distance was found in the SCT group with a mean of 7.26 mm (±0.09) and maximum distance was found in the CCT group with a mean of 7.55 mm (±0.08).

Comparison of distance between B and C

By using ANOVA test, P value was <0.05; therefore, there is a significant difference between SOT, SCT, COT, and CCT with respect to mean distance. Minimum distance was found in the SCT group with a mean of 13.82 mm (±0.10) and maximum distance was found in the CCT group with a mean of 14.10 mm (±0.09).

Comparison of distance between C and D

By using ANOVA test, P value was <0.05; therefore, there is a significant difference between SOT, SCT, COT, and CCT with respect to mean distance. Minimum distance was found in the SOT group with a mean of 8.08 mm (±0.05) and maximum distance was found in the CCT group with a mean of 8.22 mm (±0.16).

Comparison of distance between D and A

By using ANOVA test, P value was <0.05; therefore, there is a significant difference between SOT, SCT, COT, and CCT with respect to mean distance. Minimum distance was found in the COT group with a mean of 30.70 mm (±0.04) and maximum distance was found in the CCT group with a mean of 30.80 mm (±0.04).


   Discussion Top


Perfect passive fit in the interface between abutment and implant is difficult to obtain because of the different factors that affect the process of fabricating prostheses such as different system tolerance, type of abutment used, properties of metallic alloy and impression materials, investing, and casting problems. Moreover, abutment position distortion has often accompanied transfer impression techniques. The ability of the clinician to perform impression-related procedures is fundamental for the quality of the prosthesis.[3]

The common impression techniques using open and closed tray with stock metal and special acrylic trays were assessed.[4] Alan B Carr et al. and Daoudi et al. found that the direct transfer method was more accurate than the indirect transfer method.[4],[5] But Humphries et al. and Herbst et al. found that dimensional accuracy was exceptional for all the studies.[6],[7]

Direct transfer method can either be done with or without splinting. Dual cure resin and plaster have been used for splinting purpose. According to Assif et al., plaster was used for splinting the impression posts.

Kim et al. found that the nonsplint technique was more accurate during the impression-making procedure while the splint technique was more accurate during the cast fabrication procedure.[8],[9] MR Baig found that the evidence on splinting was inconclusive and the data supporting splint to nonsplint were neutral.[10] Conflicting reports were found on splinting for impression accuracy.[11],[12],[13],[14]

A single impression material polyether was chosen as it showed many superior qualities than other elastomeric impression materials. Liou et al. and Wee found no significant difference in the accuracy of impression materials using polyether and VPS impression materials and this is also supported by many other authors.[14],[15],[16],[17],[18],[19] Regarding the manipulation of the impression material, mechanical mixing of impression material was chosen since hand mixing results in air entrapment during spatulation. This leads to the formation of both surface and subsurface bubbles, which in turn may result in inaccurate dental impressions and/or jeopardize their physical properties.[20]

Comparison with the mean and standard deviation of all the groups and intragroup comparison were calculated. They were statistically analyzed using one-way ANOVA and Tukey's test as seen in [Table 1].
Table 1: Comparison of distances between A and B, B and C, C and D, and A and D with respect to methods SOT, SCT, COT, and CCT

Click here to view


For distance A to B, when the readings were evaluated [Table 1] and [Graph 1] it was observed that the readings of SOT method (7.35 mm) and COT (7.34 mm) method were more close to the reading of Master model (7.36 mm). Similarly for distances between B to C, C to D and A to D [Table 1] and [Graph 2], [Graph 3], [Graph 4] readings of SOT method and COT method are more close to that of master die as compared with SCT and CCT. This indicates that both the stock and CCTs are less accurate as compared to open tray impression techniques. This accords to the evidence of the study by Baig and Karl.[10],[21] It is supported by various studies.[5],[10],[15],[22],[23],[24],[25]



The reason for this is that the open tray impression allows the copings to be removed, along with the impression by unscrewing and the implant analogs are directly connected to these copings to fabricate the definitive cast. There is avoidance of movement of the impression copings inside the impression material throughout the procedure. Also, unscrewing the guide pins from the impression copings when the tray is removed or screwing the matching implant replicas in the impression do not cause any movement and results in an accurate cast.

When the intergroup results were compared [Table 1], it was found that the closed impression using both stock metal and custom acrylic was more inaccurate. The inaccuracy in the closed tray impression technique is similar to the findings of Jorgenson in that a permanent deformation was induced in the impression material when recovering it from structures having undercuts 1.0 mm in height and depth. The transfer coping below the height of contour could easily provide such an undercut and lead to deformation.[4],[26] This can be attributed to the linear setting expansion of the die stone [25] and after making impressions, the implant analogs could not be placed correctly at the same position. Spector et al. attributed the inaccuracies in repositioning the implant analogs to the dimensional instability of materials as well as the mechanical errors in positioning the components during the impression procedure.[11]

Subgroup comparison was done [Table 1] between SOT group and COT method. A significant difference was seen between the two (<0.001). COT readings were closer to master die readings as compared to SOT. The reason was that in the custom tray, there is a uniform thickness and an even bulk of the impression material, which leads to even contraction of the elastomeric impression material away from the specimen as it is adhered to the tray by the adhesive and not to the specimen. It was possible to make accurate stock tray impressions although the accuracy was not as consistent compared to custom tray.[27] These findings are supported by Bomberg et al. and Treml et al.[3],[28],[29],[30]

However, this study does not shows the accuracy in impressions carried out on implants placed at various angulations. Also, it does not evaluate the accuracy with impressions carried out with implants splinted with different splinting materials such as dental floss and pattern resin.


   Conclusions Top


Within the limitations of the present study, the following conclusions can be drawn:

  • The open tray impression technique is more accurate as compared to the closed tray technique
  • There is a significant effect of change in the type of trays on the accuracy of impressions
  • COT shows the most accurate impression technique among all.


Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
   References Top

1.
Balouch F, Jalalian E, Nikkheslat M, Ghavamian R, Toopchi Sh, Jallalian F, et al. Comparison of dimensional accuracy between open-tray and closed-tray implant impression technique in 15° angled implants. J Dent (Shiraz) 2013;14:96-102.  Back to cited text no. 1
    
2.
Prithviraj DR, Pujari ML, Garg P, Shruthi DP. Accuracy of implant impression obtained from different impression materials and techniques: Review. J Clin Exp Dent 2011;3:e106-11.  Back to cited text no. 2
    
3.
Burns J, Palmer R, Howe L, Wilson R. Accuracy of open tray implant impressions: An in vitro comparison of stock versus custom trays. J Prosthet Dent 2003;89:250-5.  Back to cited text no. 3
    
4.
Carr AB. Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillifac Implants 1991;6:448-55.  Back to cited text no. 4
    
5.
Daoudi MF, Setchell DJ, Searson LJ. A laboratory investigation of the accuracy of the repositioning impression coping technique at the implant level for single-tooth implants. Eur J Proshodont Restor Dent 2003;11:23-8.  Back to cited text no. 5
    
6.
Humphries RM, Yaman P, Bloem TJ. The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 1990;5:331-6.  Back to cited text no. 6
    
7.
Herbst D, Nel JC, Driessen CH, Becker PJ. Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 2000;83:555-61.  Back to cited text no. 7
    
8.
Assif D, Nissan J, Varsano I, Singer A. Accuracy of implant impression splinted techniques: Effect of splinting material. Int J Oral Maxillofac Implants 1999;14:885-8.  Back to cited text no. 8
    
9.
Choi JH, Lim YJ, Yim SH, Kim CW. Evaluation of accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models. Int J Oral Maxillofac Implants 2007;22:761-8.  Back to cited text no. 9
    
10.
Baig MR. Multi-unit implant impression accuracy: A review of the literature. Quintessence Int 2014;45:39-51.  Back to cited text no. 10
[PUBMED]    
11.
Ongül D, Gökcen-Röhlig B, Şermet B, Keskin H. A comparative analysis of the accuracy of different direct impression techniques for multiple implants. Aust Dent J 2012;57:184-9.  Back to cited text no. 11
    
12.
Spector MR, Donovan TE, Nicholls JI. An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 1990;63:444-7.  Back to cited text no. 12
    
13.
Burawi G, Houston F, Byrne D, Claffey N. A comparision of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system. J Prosthet Dent 1997;77:68-75.  Back to cited text no. 13
    
14.
Yeshwante BJ, Gaikwad SV, Baig N, Patil S, Shaikh WA. Comparative evaluation between accuracy of implant impression techniques: A systematic review. J Dent Med Sci 2015;14:30-6.  Back to cited text no. 14
    
15.
Wee AG. Comparison of impression materials for direct multi-implant impressions. J Prosthet Dent 2000;83:323-31.  Back to cited text no. 15
    
16.
Wöstmann B, Rehmann P, Balkenhol M. Influence of impression technique and material on the accuracy of multiple implant impressions. Int J Prosthodont 2008;21:299-301.  Back to cited text no. 16
    
17.
Liou AD, Nicholls JI, Yuodelis RA, Brudvik JS. Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials. Int J Prosthodont 1993;6:377-83.  Back to cited text no. 17
    
18.
Eames WB, Wallace SW, Suway NB, Rogers LB. Accuracy and dimensional stability of elastomeric impression materials. J Prosthet Dent 1979;42:159-62.  Back to cited text no. 18
[PUBMED]    
19.
Aguilar ML, Elias A, Vizcarrondo CE, Psoter WJ. Analysis of three-dimensional distortion of two impression materials in the transfer of dental implants. J Prosthet Dent 2010;103:202-9.  Back to cited text no. 19
    
20.
Di Felice R, Scotti R, Belser UC. The influence of mixing technique on the content of voids in two polyether impression materials. Schweiz Monatsschr Zahnmed 2002;112:12-6.  Back to cited text no. 20
    
21.
Karl M, Palarie V. Variables affecting the accuracy of implant master casts: An in vitro pilot study. J Dent Surg 2014;2014:6.  Back to cited text no. 21
    
22.
Lee H, So JS, Hochstedler JL, Ercoli C. The accuracy of implant impressions: A systematic review. J Prosthet Dent 2008;100:285-91.  Back to cited text no. 22
    
23.
Daoudi MF, Setchell DJ, Searson LJ. A laboratory investigation of the accuracy of two impression techniques for single-tooth implants. Int J Prosthodont 2001;14:152-8.  Back to cited text no. 23
    
24.
Lie A, Jemt T. Photogrammetric measurements of implant positions. Description of a technique to determine the fit between implants and superstructures. Clin Oral Implants Res 1994;5:30-6.  Back to cited text no. 24
    
25.
Papaspyridakos P, Chen CJ, Gallucci GO, Doukoudakis A, Weber HP, Chronopoulos V. Accuracy of implant impressions for partially and completely edentulous patients: A systematic review. Int J Oral Maxillofac Implants 2014;29:836-45.  Back to cited text no. 25
[PUBMED]    
26.
BalaMurugan T, Manimaran P. Evaluation of accuracy of direct transfer snapon impression coping closed tray impression technique and direct transfer open tray impression technique: An in vitro study. J Indian Prosthodont Soc 2013;13:226-32.  Back to cited text no. 26
    
27.
Vigolo P, Majzoub Z, Cordioli G. Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. J Prosthet Dent 2003;89:186-92.  Back to cited text no. 27
    
28.
Gordon GE, Johnson GH, Drennon DG. The effect of tray selection on the accuracy of elastomeric impression materials. J Prosthet Dent 1990;63:12-5.  Back to cited text no. 28
    
29.
Bomberg TJ, Hatch RA, Hoffman W Jr. Impression material thickness in stock and custom trays. J Prosthet Dent 1985;54:170-2.  Back to cited text no. 29
[PUBMED]    
30.
Treml A, Galvão GH, Giovanini AF, de Morais EC, Gonzaga CC, da Silva EM. Comparative evaluation of the accuracy of pick up transfer impressions performed with two different types of trays. RSBO 2013;10:128-34.  Back to cited text no. 30
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]
 
 
    Tables

  [Table 1]



 

Top
Print this article  Email this article
 
  Search
 
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Article in PDF (2,148 KB)
    Citation Manager
    Access Statistics
    Reader Comments
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusions
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed1729    
    Printed19    
    Emailed0    
    PDF Downloaded116    
    Comments [Add]    

Recommend this journal