Home | About us | Editorial board | Search | Ahead of print | Current issue | Archives | Submit article | Instructions| Reviewers

Login 
  Home Print this page Email this page Small font sizeDefault font sizeIncrease font size Users Online: 233    
     


 
Table of Contents   
ORIGINAL ARTICLE
Year : 2018  |  Volume : 8  |  Issue : 6  |  Page : 534-539
Comparative evaluation of postoperative sensitivity in bulk fill restoratives: A randomized controlled trial


Department of Conservative and Endodontics, Manubhai Patel Dental College and Hospital, Vadodara, Gujarat, India

Date of Submission13-Jun-2018
Date of Acceptance26-Aug-2018
Date of Web Publication29-Nov-2018

Correspondence Address:
Dr. Riddhi Thakarshibhai Hirani
Department of Conservative and Endodontics, Manubhai Patel Dental College and Hospital, Vadodara, Gujarat
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jispcd.JISPCD_218_18

Rights and Permissions

   Abstract 

Aim: Comparative evaluation of postoperative sensitivity (POS) among three bulk fill restorative materials (Cention N, Equia Forte, Activa™ Bioactive restorative) in Class I posterior restorations.
Materials and Methods: One hundred and forty-four patients having occlusal caries were arbitrarily selected and divided into three groups. Standardized Class I cavity was prepared and restored with Cention N, Equia forte, and Activa™ Bioactive restorative material. POS of restored tooth was assessed with a standardized cold test and air stimulus by air blow from the air syringe. Patient responses were assessed at an interval of 24 h, 1 week, and 1 month using a visual analog scale. Statistical analysis was performed using paired t-test, independent t-test, one-way ANOVA test, and Tukey's post hoc test using SPSS 11.0 program (SPSS Inc., Chicago, IL, USA) for windows.
Results: The statistical analysis showed a significant difference in the clinical evaluation of POS at 24 h interval among three groups (Cention N, Activa™ Bioactive Restorative, Equia forte). However, following 1 week and 1 month, there is no significant difference in Group C (Activa™ Bioactive Restorative).
Conclusion: POS was seen more in Cention N contrast to Equia forte and Activa™ bioactive restorative material.


Keywords: Bulk fill restorative, postoperative sensitivity, visual analog scale


How to cite this article:
Hirani RT, Batra R, Kapoor S. Comparative evaluation of postoperative sensitivity in bulk fill restoratives: A randomized controlled trial. J Int Soc Prevent Communit Dent 2018;8:534-9

How to cite this URL:
Hirani RT, Batra R, Kapoor S. Comparative evaluation of postoperative sensitivity in bulk fill restoratives: A randomized controlled trial. J Int Soc Prevent Communit Dent [serial online] 2018 [cited 2018 Dec 18];8:534-9. Available from: http://www.jispcd.org/text.asp?2018/8/6/534/246401



   Introduction Top


Timely advancement in the dentistry and the quest for the development of ideal materials to replace lost dental tissue has led to widespread use of resin-based composites to restore posterior teeth. Increasing concerns about esthetics, possibility of more conservative restorations, using the minimally invasive technique, and mercury content in the amalgam restorations have been the reasons for the determination of these materials in stress-bearing areas.[1]

In spite of being advocated for its use in areas of minimal stress historically, the expanded request has prompted a more prominent utilization of these restorations on posterior teeth, where considerable mechanical stress is generated during the function. To withstand these stresses, timely modification with the use of filler particle with various size and morphology has resulted in improved mechanical properties. Filler particles also allow for a reduction in monomer content with improved handling properties and influences postoperative sensitivity (POS), wear resistance, translucency, opalescence, intrinsic surface roughness, and polishability.[2]

In 2006, James Summit expressed that the POS occur after composite restoration because of the polymerization shrinkage as a result of which gap is formed beneath the restoration, which is then accumulated with dentinal fluid in 24–36 h. Thus, when the affected tooth is exposed to heat or stimuli, it results in expansion and contraction of dentinal fluid in the gap formed, which cause fluid movement in the dentinal tubules leading to POS.[3]

With the advances in the material sciences comes the pioneering era of “bulk-fill” composite restoratives that are alleged to allow the build-up of composite restorations in layers up to 4–5 mm. Bulk-fill composite materials have some advantages over the conventional composites including increased depth of cure and low shrinkage stress.[4]

Equia (GC America INC) is a new glass ionomer (GI) restorative system. It is a combination of a self-adhesive, chemically cured, highly filled GIC (FUJI IX GP EXTRA, GC) and a self-adhesive, light cured, filled resin surface sealant (G-COAT PLUS, GC). This material has the property of increased fracture toughness, flexural strength, and flexural fatigue resistance which is required in Class I restorations.[5]

Cention N (Ivoclar vivodent) is tooth-colored restorative material with high flexural strength. It belongs to the materials group of Alkasites and basic filling material for direct restorations. It can be used as a full volume (bulk) replacement material.[6]

Activa™ bioactive (Pupldent) is a highly innovative, biologically agile and an esthetically pleasing composite material that incorporates all the advantages of GI cements in a strong, resilient resin matrix. It is the first biologically agile composite with an ionic resin matrix, a shock absorbing resin component and bioactive fillers that mimic the chemical as well as physical properties of natural dentition.[7],[8],[9],[10],[11]

So far, there have been limited numbers of studies available in the literature investigating POS after incremental resin composites and bulkfill composites restoration placement. Therefore, the aim of this study is to clinically evaluate the POS among Equia Forte, Cention N and Activa™ Bioactive Restorative in Class I restoration using visual analog scale (VAS).


   Materials and Methods Top


The present study is a randomized controlled trial with proposed requirement of total 144 patients or sites equally divided into three groups or subsites to check mean VAS score difference between groups by 2.1 with standard deviation 4.5 at 5% risk and 80% power. Arbitrary selection of 144 patients, both males and females, aged between 18–45 years, diagnosed as having Class I dental caries in a maxillary/mandibular premolar or molar was done from the Outpatient Department of Conservative Dentistry and Endodontics, Manubhai Patel Dental College and Hospital, Vadodara. Informed consent from all the patients was taken. Charting of records–medical and dental history was done. The diagnosis was done by clinical examination and intraoral periapical radiographs. This study protocol was approved by Research and Ethical Committee at Manubhai Patel Dental College and Hospital (Approval No.-MPDC_115/CONS-20/17). All the patients were diagnosed with a class I dental caries and divided into three groups.

The following cases were excluded from the study:

  1. Teeth with the presence of any pathologic pulpal disease with or without pain.
  2. Teeth with previous restorations, any defective restoration adjacent to or opposing the affected tooth.
  3. Teeth with surface loss due to attrition, erosion, abrasion, or abfraction.
  4. Patients with poor oral hygiene, severe, or chronic periodontitis.
  5. Patients having allergy to the materials used in this trial.


The experimental groups

With a specific end goal to do a comparative evaluation of post operative sensitivity (POS) using different bulk fill restorative material, the test bunches were randomly divided as follows:

  • Group A: Cention N
  • Group B: Equia forte
  • Group C: Activa™ Bioactive restorative


The material used for cavity preparation included Diagnostic instruments, Rubber dam kit (GDC), Highspeed air turbine handpiece (NSK INC. Japan), Round diamond bur (Mani INC. Japan) and No. 245 straight fissure diamond bur (Mani INC. Japan). Restorative material was placed using 34% tooth conditioner gel (3M ESPE, USA), lightemitting diode light curing unit, threeway airwater syringe, Cention N (IVOCLAR VIVADENT), Equia forte (GC America INC), Equia coat (GC America INC), Capsule applier III, Capsule mixture, Activa™ bioactive restorative (PULPDENT), and Teflon coated composite placement hand instruments (GDC). Finishing and polishing were accomplished with composite finishing and polishing kit (SHOFU INC. JAPAN) [Figure 1].
Figure 1: Armamentarium for the restorative procedure

Click here to view


Cavity preparation

Isolation was done with the help of a rubber dam (GDC/HU FRIEDY) followed by Class I cavitiy preparation.

The overall dimensions and depth of cavities were standardized follows

  • 1.5 mm from central groove
  • 4 mm in length mesiodistally
  • 2 mm bucco-palatally.


Class I cavity was prepared by removing caries using a round and NO.245 straight fissure diamond bur (Mani Inc., Japan) in a high-speed air-turbine handpiece (NSK INC., Japan) with copious water irrigation. Burs were replaced after every eight preparation.

Restoration placement procedure

Group A: Cention N

Class I cavity was rinsed thoroughly with water and dried. One measuring scoop of powder and one drop of liquid (this corresponds to a weight ratio of 4.6:1) was taken. The powder was isolated into two similarly substantial parts utilizing a plastic spatula. The fluid was spread to expand the surface. The main part of powder was blended with the whole fluid administered on the blending cushion. After every one of the segments has been altogether mixed, outstanding powder was included and mixed again until (45–60 s) a homogeneous consistency was accomplished. The working time was 3 min from the beginning of mixing. The material was applied to the cavity, carefully adapted and condensed. Any occlusal excess was removed; the restoration was light-cured after placement for 40 s followed by finishing, polishing and checking of occlusion for any high points [Figure 2]a and [Figure 2]b.
Figure 2: (a) Preoperative image-Cention n, (b) postoperative image-Cention n

Click here to view


Group B: Equia forte

Cavity was rinsed thoroughly with water and dried with cotton pellet or by gently blowing with the three-way syringe. Cavity was etched with 37% phosphoric acid (3M ESPE, Scotch bond) for 15 s and rinsed with water for 15 s, followed by drying. The capsule was placed into a metal GC Capsule applier and activated just before mixing and used immediately and set into a mixer and mixed for 10 s. The mixture was removed immediately from the capsule and extruded directly into the preparation. After that was the application of EQUIA Forte coat and light cure for 20 s followed by finishing, polishing, and checking of occlusion for any high points [Figure 3]a and [Figure 3]b.
Figure 3: (a) Preoperative image - Equia forte, (b) postoperative image - Equia forte

Click here to view


Group C: Activa™ bioactive restorative

Class I cavity was etched using 37% phosphoric acid (3M ESPE, Scotch bond) for 10 s, rinsed with water for 15 s. Water was expelled from the rinsed cavity with a gentle blow of air and was blot dried, leaving a moist surface. Mixing tip was placed on the Activa™ bioactive restorative syringe, syringe inserted into ACTIVA™ bioactive restorative–SPENSER and snapped into place using firm pressure. The material was dispensed using gentle pressure. 1–2 mm of material was dispensed onto a mixing pad and discarded to check the even mix of the base and catalyst. The restoration was light-cured for 20 s followed by finishing, polishing and checking for any high occlusal points [Figure 4]a and [Figure 4]b.
Figure 4: (a) Preoperative image - Activa™ bioactive restorative, (b) postoperative image - Activa™ bioactive restorative

Click here to view


POS was assessed of each restored tooth at an interval of 24 h, 1 week, and 1 month using the VAS score with a standardized cold test [Figure 5] and air stimulus by air blown from the air syringe with a standardized distance of 5 mm (45 psi). The patient responses were then assessed using a VAS scoring index. The VAS is a 10-cm line with the anchor words “no sensitivity” (0 cm) at one end and “intolerable sensitivity” (10 cm) at the other end. Every patient was requested to place a vertical mark on the VAS line to indicate the intensity of sensitivity level after the administration of the stimuli for each tooth and determined the sensitivity scores and quantified each patient's response to each restoration by measuring the distance in cm from the anchor word (0 cm) to the mark.
Figure 5: Assessment of postoperative sensitivity with cold test

Click here to view


Statistical analysis

Data analysis was performed by utilizing the following statistical tests:

  • Descriptive statistics (mean, SD, CI)
  • Paired t-test
  • Independent t-test
  • One way ANOVA test
  • Tukey's post hoc Tests
  • The mean and standard deviation of the POS was calculated for each group. The data showed normal distribution, and there was homogeneity of variances between the groups. The results were evaluated with a 95% confidence interval. The significance level was set at <0.05. All statistical analyses were conducted using SPSS 11.0 program (SPSS Inc., Chicago, IL, USA) for windows. The Comparison of mean values of two groups was done using independent ‘t’-test for two sample means. Paired t-Test was carried out to compare mean value between the time period (1 day, 1 week, and 1 month) [Table 1], [Table 2], [Table 3].
Table 1: Independent t-test for cention-N

Click here to view
Table 2: Independent t-test for equia restorative

Click here to view
Table 3: Independent t-test for active bioactive restorative

Click here to view



   Results Top


In the present study, a total of 144 patients were considered. Of the total 144 patients, 119 patients treated were between ages 18–30 years. The statistical analysis showed a significant difference in the clinical evaluation of POS at 24 h among three groups (Cention N, Activa™ Bioactive Restorative, Equia forte) but after 1 week and 1 month interval, there was no significant difference in Group C (Activa™ Bioactive Restorative) [Graph 1] and [Table 1], [Table 2], [Table 3].




   Discussion Top


Contemporary resin composite restorative materials reveal good clinical performances for the restoration of posterior teeth. Nonetheless, POS is a well-known problem with the resin composite restorations.[4]

Age is an important factor. Young patients have larger pulp chambers and larger dentinal tubules, making it more likely that their teeth would be more sensitive to hydrodynamic stimuli as compared to older individuals in which partial or complete obturation of canals, sclerosis; secondary dentin formation due to caries may reduce the sensitivity. In this study, most of the patients belong to the age group between 18–30 years.[4],[5]

Bulk-fill resin composites are novel direct restorative materials. However, the incidence of POS with bulk fill restorative resin, and its comparison with incremental composite resin is yet to be answered before deciding the use of bulk-fill composites as a standard of care for the restoration of teeth with profound decay.[4]

POS at the interval of 24 h, 1 week, and 1 month was assessed using cold test and air blast test with VAS. It is a subjective assessment method, a VAS (values 0–10) providing effective statistical test evaluation and exact measure of pain.[12] It was found to be higher in patients treated with Cention N (29.2%) followed by Equia forte (12.5%), and Activa™ Bioactive (4.2%) being the least at an interval of 24 h. Less POS in patients restored with Activa™ bioactive is attributed to the biologically active ionic resin matrix, reactive, and shock absorbing rubberized GI fillers in the active which chemically bonds and seals teeth against bacterial leakage. Dynamic system of ionic exchange with saliva and tooth structure, continuously releasing and recharging calcium, phosphate and fluoride ions and reacting to pH changes in the mouth. Activa™ bioactive restorative triggers the mineral apatite formation and remineralization, which is the defining requirement of bioactive materials. This process unites the restoration and the tooth together, penetrates and fills micro-gaps, reduces sensitivity, guards against secondary caries, and seals margins against micro-leakage and failure.[7],[8],[9],[10],[11] These results were in congruence with the findings of the research study by the pulpdent corporation who noted some level of postoperative hypersensitivity in 5% of patients treated with active bioactive restorative at 1 year recall, gradually becoming insignificant.[13]

The high incidence of postoperative hypersensitivity with Cention N restorations can be attributed to low volumetric shrinkage due to organic, monomer part in the liquid of Cention N. The liquid contains different dimethacrylates which represent 21.6% wt. of the final mixed material. A combination of Urethane dimethacrylate (UDMA), Tricyclodecan-dimethanol dimethacrylate, an aromatic-aliphatic-UDMA and Polyethylene glycol 400 dimethacrylate (PEG-400 DMA) cross-links during polymerization resulting in strong mechanical properties and good long-term stability but also a low volumetric shrinkage. The organic/inorganic ratio also affects the volumetric shrinkage leading to postoperative hypersensitivity.[6]

Equia Forte is glass composite metamorphoric material, achieved through the addition of ultrafine, highly reactive glass particles disseminate within the conventional GI and higher molecular weight polyacrylic acid. The resultant new glass blend formulation builds a high strength restorative material. Adhesion of EQUIA which uses Fuji IX GP Extra, a highly filled GIC, to dentin occurs by a micromechanical interlocking and a chemical bonding with the hydroxyapatite in enamel and dentin. These metaphoric alteration results in a robust, bulk-fill GI restorative system with excellent physical properties, esthetics and possibly less hypersensitivity.[5]

The results of the air blast test and cold test used to evaluate postoperative hypersensitivity were identical with the findings obtained with the VAS.

The uniqueness of this study lies in the fact that it is the first of its kind in vivo study performed to evaluate postoperative hypersensitivity between these materials with uniform age group patients distributed in all the study groups. It is performed by single operator with multiple tests adopted (Cold test, Air blast test, VAS) to rule out any possibility of subjective bias.

Shortcomings of this study include inadequate sample size and limited duration of follow-ups to prove the long-term success of these materials.

Further in vivo studies with these materials in all types of cavity preparations with a larger sample size and long-term follow-ups deems necessary to use them as materials of choice for restorative procedures. Other factors including anatomic form, color match, marginal adaptation, marginal discoloration, surface texture, and secondary caries need to be evaluated to assess long-term versatility of these materials.


   Conclusion Top


Based on the findings of the current in vivo study, it may be concluded that-

  1. Initial post operative sensitivity (at interval of 24 hours) is seen least with Activa™ bioactive restorative material as compared to Equia forte and Cention N
  2. Post operative sensitivity is absent with Activa™ bioactive restorative material at the interval of 1 week and 1 month, while it is still present in patients treated with Equia forte and Cention N (highest).


Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Gianordoli-Neto R, Padovani GC, Mondelli J, de Lima Navarro MF, Mendonça JS, Santiago SL, et al. Two-year clinical evaluation of resin composite in posterior teeth: A randomized controlled study. J Conserv Dent 2016;19:306-10.  Back to cited text no. 1
[PUBMED]  [Full text]  
2.
Ibarra ET, Lien W, Casey J, Dixon SA, Vandewalle KS. Physical properties of a new sonically placed composite resin restorative material. Gen Dent 2015;63:51-6.  Back to cited text no. 2
    
3.
Dhanapal D, Sureshbabu NM. Comparison of postoperative sensitivity using two flowable composites in noncarious cervical lesions: A randomized controlled blinded trial. J Oper Dent Endod 2017;2:55-60.  Back to cited text no. 3
    
4.
Ayer MK. Postoperative sensitivity after placement of bulk-fill posterior restoration. J Res Med Dent Sci 2017;5:53-8.  Back to cited text no. 4
    
5.
Vaid DS, Shah NC, Bilgi PS. One year comparative clinical evaluation of EQUIA with resin-modified glass ionomer and a Nanohybrid composite in noncarious cervical lesions. J Conserv Dent 2015;18:449-52.  Back to cited text no. 5
[PUBMED]  [Full text]  
6.
Samanta S, Das UK, Mitra A. Comparison of microleakage in class V cavity restored with flowable composite resin, glass ionomer cement and centionn. Imp J Interdiscip Res 2017;3:180-83.  Back to cited text no. 6
    
7.
Zmener O, Pameijer CH, Porta RD, Hernandez S, Serrano SA. Marginal Bacterial Leakage in Class I Cavities Filled with a new Resin-Modified Glass Ionomer Restorative Material; 2013.  Back to cited text no. 7
    
8.
Garcia-Godoy F, Morrow BR, Pameijer CH. Flexural strength and fatigue of new Activa RMGIs. J Dent Res 2014;93:254.  Back to cited text no. 8
    
9.
Slowikowski L, John S, Finkleman M, Perry R, Harsono M, Kugel G. Fluoride ion release and recharge over time in three restoratives. J Dent Res 2014;93:268.  Back to cited text no. 9
    
10.
Alrahlah A. Diametral tensile strength, flexural strength, and surface microhardness of bioactive bulk fill restorative. J Contemp Dent Pract 2018;19:13-9.  Back to cited text no. 10
    
11.
Rusin RP, Fitch JA, Aeschliman DB, Cummings KM. Ion release from a new protective coating. AADR Annual Meeting; 2011.  Back to cited text no. 11
    
12.
Kersten P, White PJ, Tennant A. Is the pain visual analogue scale linear and responsive to change? An exploration using Rasch analysis. PLoS One 2014;9:e99485.  Back to cited text no. 12
    
13.
Activa™ Bioactive Restorative. The Dental Advisor; 2017. Available from: https://www.dentaladvisor.com/evaluations/activa-bioactive- restorative-1-yr/. [Last accessed on 2018 Sep 24].  Back to cited text no. 13
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]
 
 
    Tables

  [Table 1], [Table 2], [Table 3]



 

Top
Print this article  Email this article
 
  Search
 
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Article in PDF (1,646 KB)
    Citation Manager
    Access Statistics
    Reader Comments
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed98    
    Printed5    
    Emailed0    
    PDF Downloaded19    
    Comments [Add]    

Recommend this journal